This procedure explains how to clean or replace the Y-screen for the Pre-Blast Pump. These steps can also be applied to other Y-screens throughout the wash.
Note: The Y-screen shown in this video represents a worst-case scenario of debris buildup. With consistent weekly cleaning, Y-screens can typically be cleaned and reused rather than replaced, provided the screen and seal remain in good condition.
This procedure requires the wash to be closed and will take approximately fifteen minutes to complete.
Safety
Before beginning, wear the required PPE, including safety glasses, nitrile gloves, and hearing protection as required by site conditions.
Required Tools and Materials
Required tools and materials include a 13/16-inch socket, a ratchet, and the appropriate replacement Y-screen, if necessary.
Replacement No. 50 Mesh Screens 1" NPT - Pack of 5 (P-WAT-3123)
Replacement No. 20 Mesh Screens 2" NPT - Pack of 5 (P-WAT-3124)
Procedure
-
Identify the Y-screen that needs cleaning or replacement, then set the corresponding pump and valve functions to OFF in the Wash Controller.
WARNING: Operating the pump with the water supply shut off can damage the pump. Ensure the pump and valve are turned OFF in the Wash Controller before proceeding.
- Close the water supply ball valve feeding the pump.
- Using a 13/16-inch socket and ratchet, loosen and remove the cap located at the bottom of the Y-screen housing. Then, remove the Y-screen.
- Thoroughly rinse the cap, seal, and Y-screen to remove any debris or buildup.
- Inspect the screen and seal for holes, tears, or other signs of damage. If the Y-screen is damaged, replace it with one of the appropriate size.
- Reinstall the cleaned or replacement Y-screen and cap into the housing, ensuring the screen and seal are properly seated.
- Tighten the cap securely, being careful not to overtighten.
- Slowly reopen the water supply ball valve to restore water to the pump.
Verify Operation
- On the Wash Controller, manually activate the corresponding valve and pump functions or return the function to AUTO.
- Verify that the pump operates normally, the application sprays as expected, and there are no leaks around the Y-screen housing.
Escalation
If the issue persists, contact Equipment Support at 616-795-4892 for further assistance.